REVELSTOKE

WORKPLACE HEALTH & SAFETY COMMITTEE

MINUTES  – June 10, 2004

             

COMMITTEE MEMBERS:

 

Management:          Stan Bell        Fops Service Area Manager   250-837-8219 (Co-Chairman)

                              Brad Riches    ATMS                                  250-837-8236 

                               Doug Cassell   S&C Manager                     250-837-8212

                         

Union Rep:              Bob Gardali       Conductor-TCRC                250-837-8225 (Co-Chairman)

                              Roy Williams     L/E-TCRC                          250-837-8225

      Kent Jones      B&S            Rev                             250-837-8227 

                              Jodi Grant        ES TMF Glacier                   250-837-8289

                              Phil Parr          S&C            Mtnr-Glacier                250-837-8206

                             

 

 

Held:                June 10, 2004, Revelstoke, BC

Co-Chairman:    B. Gardali

 

Members in Attendance:

Management:    K. Sali, B. Riches, D. Cassell

Union Reps :     B. Gardali, R. Williams, K. Jones, P. Parr, A. Stewart, S. Miller

 

Meeting called to order 0935.  Minutes of May 13, 2004 meeting read and adopted.

 

SAFETY ACTION PLANS

 

 

UNFINISHED BUSINESS:

                                                                                                                       

Item 0312-02: Paul Bede suggests conversations with Diesel Dr take place on a channel other than standby or

CP 14, which is used by ES – prevents ES communication.

Action (0406)    S. Bell advised issue has been raised to NMC and Diesel Dr for consideration.

                                                                                                                                    MOTION TO CARRY

 

Item 0405-01:  K. Jones advised he witnessed contractors unloading a tank car in Revelstoke Yard using unsafe practices with no protection.  Another incident was unloading of logs.

Action (0406)    Discussion revealed there must be procedures in place, possibly find an alternative location, repair spur track.

                        K. Sali advised he spoke with the Account Manager at Downie and advised him the ‘test’ period is over with using the yard and they must advise with a permanent solution, ie upgrading their spur or finding an alternative location.  With regard to the unloading of the tank cars, this was done by a Contractor unfamiliar with our safety rules – Downie has also been advised they must ensure they advise their contractors accordingly.                                                    MOTION TO CARRY

 

Item 0405-02:  Roy Williams requested clarification with regard to a previously discussed proposed procedure for Rule 40.1 - ES to use flags and locks when working on track even though rule states lock or red flag.

Action (0406)    B. Riches indicated he has advised his employees.  TP&E must also be advised with the gangs moving in on our territory – D. Harder/B. Rota to handle.

                        T. Marinier to further advise.                                                                 MOTION TO CARRY

CORRESPONDENCE & BUSINESS ARISING

 

Bob received a letter from an employee of an alleged signal irregularity (Signal 342) – D. Cassell will investigate.

 

INCIDENT REVIEW

 

Incident                                         Location                Cause                                      Prev. Measures

Run Thru Switch

NON
FRA

Golden Yard

05.14.04  1825

Switch not lined for intended movement

Informal investigation

Swelling to left eye area

NON
FRA

Kamloops Bnk

05.15.04  1720

Possible bite or string

Furniture / vent  cleaning of bunkhouse

Slipped and fell down stairs in unit – twisted ankle

LTI

FOPS

M.119.9 Mtn

05.19.04  0630

Slipped down stairs

IRR with employee

Pulled calf muscle entraining unit

LTI

FOPS

Field Station

05.27.04  2210

Undetermined

Discuss with employee

Train passed stop signal

CRV

FOPS

M.55.60 Shu

05.29.04  0948

Investigating

Investigating

Dust in right eye – pking train

NON
FRA

M.39.0 Shu

05.31.04 Shu

Foreign particle entered eye – safety glasses worn

IRR with employee

 

 

SAFETY HAZARD REPORTS  (Incomplete)

 

SHR0212-03:              MU cables laying around on the ground at Ducks, Chase and Squilax

Action (0406)    Item brought back to table account unsure of status of installation of brackets at various locations. Greely, Moberly and Squilax outstanding.                                                MOTION TO CARRY                                                                                                                                                                                                                                                                                                                                                

SHR0310-07:  Issue with VRU – being rested for duty

Action (0405)    K. Sali advised that MTPL is an ongoing issue and will try to have OM’s update to reflect a more accurate lineup.  Bob indicated he would like to push this issue to a higher level.  Stan Bell indicated this issue has been raised to National H&S Committee.  Bob indicated to carry in minutes to track.  Bob further recommended NMC representation for an upcoming 4 hour safety meeting.      

                         MOTION TO CARRY                                                                                                

                                                                       

SHR0401-04:  Field Bunkhouse – entranceway covered in ice and poorly lit.

Action (0406)    J Creighton/Facilities to advise –suggestion to relocate entrance. 

                        Neil Higgins advised lights have been installed             MOTION TO CARRY                        

 

SHR0401-07:  White out conditions – being brought into slide path after red form being issued.

Action (0406)    S. Bell to arrange a conference call with NMC and possibly RTC B McAstocker for September/October in preparation for winter.         MOTION TO CARRY                                                                                                                                                

 

SHR0403-01:  Employee parking lot Victoria Road – slip, trip hazard, large pooling of water.

Action (0406)    Tim Marinier indicated some work could be undertaken with installation of a drainage pipe/catch basin.  Parking lot has been graded and sprayed.

                        Committee would still like to see above recommendations completed.       MOTION TO CARRY

                                                                                                           

SHR0404-05:  Revelstoke Station Platform – excess sand and gravel on platform

Action (0406)    B&B have taken under advisement – will be tended to as time / manpower permits.

                        MOTION TO CARRY            

 

SHR0404-07:  Kenwood radios are not working – trainee’s radio could not be heard one car length away – would not transmit.

Action (0406)    Bob informed committee complaints are being documented with regard to these radios.

D. Cassell advised testing is being done with various antennas.     Complaints seem to be system wide.  Committee will monitor.                MOTION TOCARRY

 

SHR0404-08:  Called for 0250 and waited over an hour for train.  Better calls or a rest area in station.

Action (0406)    Committee to investigate setting up a rest area in station.     MOTION TO CARRY

 

 

 

SAFETY HAZARD REPORTS   (New)

 

SHR0504-01:  West Back Track Switch Lock – Chase – needs to be pounded open.

Action (0406)    TMS E Palasz advises lock was replaced May 31st.      MOTION TO DELETE

 

 

SHR0504-02:  Mile 96.5 Mountain Sub – location of large slide – old power pole holes are exposed – one has cables protruding – extreme hazard in darkness.

Action (0406)    S&C found only one hole, south “H” structure pole, there was no hole for the north one.  Hole has been filled in and area checked for other possible holes-none were found.  Cables were checked and determined that they were dead and were cut off at below ground level.          MOTION TO DELETE

 

REPORTS OF SUB-COMMITTEES

 

Mock Evacuation – Revelstoke – tentatively scheduled for end of September.

 

 

DISTRICT SAFETY ADVISOR REPORT – N/A

 

 

NEW BUSINESS

 

Item 0406-01:  K. Jones report crossing at Shops (House & Wye) is in very rough shape – requires new planks

Action:              TMS Palasz to advise.

 

 

 

 

  

L. Sali

For S. Bell/ B. Gardali